Service actions according to Intervals
Service plan A 4000 running hours
Service plan A and B 8000 running hours
Service plan A 12000 running hours
Service plan A, B and C 16000 running hours
... ...
Procedure
Starting from the Main screen (see Main screen menu):
• Press the key “Menu” (F1).
• Press the arrow down key (1) until “Service” is followed by a horizontal arrow.
• Activate the menu by pressing tabulator key (2).
• A screen similar to the one below appears:
“Service Timer”
“Running Hours”
7971 “hrs”
“Menu” “Reset”
F1 F2 F3
• The screen shows that the total compressor running time is 7971 hours.
• Press the tabulator key (2), following screen appears:
“Next Timer”
“Level” A B
8000 “hrs”
“Back” “Reset”
F1 F2 F3
• The screen shows that the next service plans to be carried out are plans A and B and that these plans are
to be carried out every 8000 running hours.
• Press the arrow down key (1) to find out which service plans were carried out previously, following screen
appears:
“Previous Timer”
“Level” A
4008 “hrs”
“Back”
F1 F2 F3
• The screen shows that plan A was carried out at 4008 running hours.
• Stop the compressor, switch off the voltage and carry out the service operations related to the indicated
service plans, see section Preventive maintenance schedule.
• Switch on the voltage and scroll to the “Next Timer” service screen.
• Press the “Reset” button (F3). Confirm the question for resetting.
Instruction book