  • R
    Robert RodriguezAug 15, 2025
    What to do if Atlas PV-12PX lift raises slowly?
    • P
      Pamela EllisAug 15, 2025
      If the Atlas Lifting Systems lift raises slowly, it could be due to several factors. The oil line might be jammed and needs cleaning. The motor could be running on low voltage, requiring a check of the electrical system. The oil might be mixed with air, necessitating filling the tank. The gear pump could be leaking and needs replacement, or the lift might be overloaded, requiring a check of the load.
  • J
    Jennifer GrayAug 18, 2025
    What to do if Atlas PV-12PX motor runs but the lift is not raised?
    • G
      Grace LawrenceAug 18, 2025
      If the motor runs but the lift is not raised, it could be due to the motor running in reverse rotation, in which case you should reverse two power wires. Alternatively, the gear pump could be out of operation, or the release valve, relief valve, or check valve could be damaged, all requiring repair or replacement. Also, check for low oil level and fill the tank if needed.
  • V
    Victoria SmithAug 21, 2025
    Why Atlas PV-12PX lift does not stay up?
    • B
      Benjamin BryantAug 21, 2025
      If the Atlas Lifting Systems lift does not stay up, it could be due to the release valve being out of work, the relief valve or check valve leaking, or the cylinder or fittings leaking. In each case, the suggested solution is to repair or replace the affected component.
  • S
    Sandra EnglishAug 25, 2025
    How to fix Atlas Lifting Systems lift that cannot lower?
    • M
      maciasjamesAug 25, 2025
      If the Atlas Lifting Systems lift cannot lower, it may be because the safety devices are activated (release the safeties), the release valve is damaged (repair or replace), the safety cable is broken (replace), or the oil system is jammed (clean the oil system).
  • N
    Nancy HensleyAug 27, 2025
    Why is my Atlas Lifting Systems lift raising so slowly?
    • A
      Angel WarrenAug 27, 2025
      If the Atlas Lifting System lift raises slowly, there might be several reasons: * The oil line could be jammed, in which case you should clean it. * The motor might be running on low voltage, so it's recommended to check the electrical system. * The oil could be mixed with air, requiring you to fill the tank. * The gear pump might be leaking, necessitating a replacement pump. * The lift might be overloaded, so you should check the load.
  • R
    Randy BarnesAug 30, 2025
    What to do if my Atlas Lifting Systems lift cannot lower?
    • H
      Holly HoffmanAug 31, 2025
      If your Atlas Lifting System lift cannot lower, consider these possible causes: * The safety devices may be locking, so release the safeties. * The release valve might be damaged, requiring repair or replacement. * The safety cable could be broken, so replace it. * The oil system might be jammed, so clean the oil system.
  • J
    James SheltonSep 2, 2025
    Why does the motor run but the lift is not raised in my Atlas Lifting Systems?
    • W
      williamsjohnSep 2, 2025
      If the motor in your Atlas Lifting System runs but the lift does not raise, consider the following: * The motor might be running in reverse rotation, in which case you should reverse two power wires. * The gear pump could be out of operation, requiring repair or replacement. * The release valve might be damaged, so repair or replace it. * The relief valve or check valve could be damaged, necessitating repair or replacement. * The oil level might be low, so fill the tank.
  • P
    Paul DanielSep 5, 2025
    What to do if Atlas Lifting Systems lift does not stay up?
    • C
      Casey WeaverSep 6, 2025
      If your Atlas Lifting System lift does not stay up, it could be due to: * A release valve that is out of work, requiring repair or replacement. * Leakage in the relief valve or check valve, so repair or replace them. * Leaks in the cylinder or fittings, and you should repair or replace them.
  • J
    James GraySep 8, 2025
    Why Atlas PV-12PX Lifting Systems motor does not run?
    • R
      Ryan DukeSep 8, 2025
      The Atlas Lifting Systems motor might not be running due to several reasons: the start button may not be working and needs replacement; the wiring connections might be in poor condition and need repair; the motor could be burned out, requiring repair or replacement; the AC contactor might be burned out and needs replacement; or the height limit switch could be damaged and needs repair or replacement.
  • R
    ronald04Sep 12, 2025
    What to do if the motor of my Atlas Lifting Systems does not run?
    • R
      Robert SmithSep 12, 2025
      If the motor of your Atlas Lifting System does not run, the potential causes and solutions are as follows: 1. The start button may not be working, in which case you should replace the start button. 2. The wiring connections might be in poor condition, requiring you to repair all wiring connections. 3. The motor could be burned out, and you should repair or replace it. 4. The AC contactor might be damaged, so replace or repair it.

Summary

Specifications

Clear-Floor Direct-Drive Model Features

Details features of the clear-floor, direct-drive lift model.

Installation Requirements

Concrete Specifications

Outlines critical concrete requirements for safe lift installation.

Power Supply

Specifies the electrical requirements for the lift's power unit.

Installation Steps

Installation Location

Guidance on selecting and preparing the optimal site for the lift.

Install safety device

Installing the lift's safety mechanisms.

Install Electrical System

Test Run

Test with load

Performing operational tests with a vehicle load.

Operation Instructions

To lift vehicle

Step-by-step guide for safely lifting a vehicle.

To lower vehicle

Step-by-step guide for safely lowering a vehicle.

Maintenance Schedule

Trouble Shooting

Motor does not run

Common causes and remedies for motor failure.

Motor runs but the lift is not raised

Troubleshooting steps for a lift that won't elevate.

Lift does not stay up

Solutions for a lift that fails to maintain its height.

Lift raises slowly

Diagnosing and fixing slow lift operation.

Lift can not lower

Remedies for a lift that cannot be lowered.