CRAFT LINE INTERFACE (CLI)
TranScend Chassis – Operation Manual 5-5
NOTE: TranScend chassis is con gured to factory time prior to shipment. It does not make local
time adjustment (e.g. daylight saving time) automatically.
Hostname: Displays or con gure the system hostname.
Example #1: In this example, user requested to con gure the hostname “InnoTrans”. And the system indicates the
command execution as “Successful”.
Transcend[slot-1] >hostname InnoTrans
Successful
Community: Displays or con gures the SNMP community string. Up to three community strings are supported. The system
default community string is “public” with read only permission.
Example #1: In this example, user requested to add a community string “inno” with read-write permission. And the
system indicates the command execution as “Successful”.
Transcend [slot-1] >community add inno rw
Successful
Exampel #2: In this example, user requested to add a community string name “inno” with read-only permission.
And the system indicates the command execution as “Successful”
Transcend [slot-1] >community add inno
Successful
TrapAddr: Displays or con gures the SNMP trap destination IP addresses. Up to two trap addresses are supported.
Example #1: In this example, user requested to add a trap destination, 192.168.1.137. And the system indicates
the command execution as “Successful”.
Transcend [slot-1] >trapaddr add 192.168.1.137
Successful
sysContact: Displays or con gures the SNMP system contact information.
Example #1: In this example, user con gures the SNMP system contact information as “snmp@inno-trans.com”.
And the system indicates the command execution as “Successful”.
Transcend [slot-1] >sysContact snmp@inno-trans.com
Successful
SysLocation: Displays or con gures the SNMP system location information.
Example #1: In this example, user con gures the SNMP system location information as “Bldg 10, San Jose, CA”.
And the system indicates the command execution as “Successful”.
Transcend [slot-1] >sysLocation bldg 10, San Jose, CA
Successful