CRAFT LINE INTERFACE (CLI)
TranScend Chassis – Operation Manual 5-11
Transcend [slot-1] >LaserTempAlarm
MajorLoLo
OpticalPowerAlarm: Displays the alarm status of optical power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical power as “MajorLoLo” (e.g.
Major alarm with power reading below the low low threshold).
Transcend [slot-1] >OpticalpPowerAlarm
MajorLoLo
LockAlarm: Displays the alarm status of synthesizer lock. It’s an alarm condition when synthesizer loses its lock.
Example #1: In this example, the module in slot 1 reports the alarm status of synthesizer lock as “Major” on
channel 1.
Transcend [slot-1] >LockAlarm 1
Major
ModuleTempAlarm: Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempalarm
Normal
5.1.2.7 Optical Switch
The commands in this section are Optical Switch specic.
ModuleTemp: Displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade.
Transcend [slot-1] >ModuleTemp
+21.4 (deg C)
OPinPower: Displays the optical input power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical input power reading on input #1 (p.s. primary
optical input).
Transcend [slot-1] >OPinPwer 1
+3.0 (dBm)
Switch: Displays the optical switch position.
Example #1: In this example, the module in slot 1 reports its optical switch position as on primary input.
Transcend [slot-1] >switch
primary
thresholddBm: Display threshold setting.
CHAPTER 5: CHAPTER 5: