CRAFT LINE INTERFACE (CLI)
TranScend Chassis – Operation Manual 5-7
5.1.2.3 PON EDFA
The commands in this section are PON EDFA specic.
ModuleTemp: Displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade.
Transcend [slot-1] >ModuleTempAlarm
+21.4 (deg C)
LaserTemp: Displays the laser temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its laser temperature reading on channel 1.
Transcend [slot-1] >LaserTemp 1
+23.0 (deg C)
LaserBias: Displays the laser bias reading in mA.
Example #1: In this example, the module in slot 1 reports its laser bias reading on channel 1.
Transcend[slot-1] >LaserBias 1
+0.0 (mA)
OPinPower: Displays the optical input power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical input power reading.
Transcend [slot-1] >OPinPower
-99.0 (dBm)
OPoutPower: Displays the optical output power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical output power reading.
Transcend [slot-1] >OPoutPower
-99.0 (dBm)
LaserTempAlarm: Displays the alarm status of laser temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of laser temperature on channel 1 as
“MajorLoLo” (e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >LaserTempAlarm 1
MajorLoLo
OPinPowerAlarm: Displays the alarm status of optical input power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical input power as “MajorLoLo”
(e.g. Major alarm with power reading below the low low threshold).