CRAFT LINE INTERFACE (CLI)
TranScend Chassis – Operation Manual 5-17
Transcend [slot-1] >gain
20 (dBm)
Attenuation: Displays the user attenuation setting.
Example #1: In this example, the module in slot 1 reports its attenuation setting as 0 on channel 1.
Transcend [slot-1] >attenuation 1
0
OPinPowerAlarm: Displays the alarm status of optical input power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical input power as “MajorLoLo”
(e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >OPinPowerAlarm
MajorLoLo
OPoutPowerAlarm: Displays the alarm status of optical output power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical output power as “MajorLoLo”
(e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >OPoutPowerAlarm
MajorLoLo
GainAlarm: Ddisplays the alarm status of gain.
Example #1: In this example, the module in slot 1 reports the alarm status of gain as “MajorLoLo” (e.g. Major alarm
with power reading below the low low threshold).
Transcend [slot-1] >gainAlarm
MajorLoLo
ModuleTempAlarm: Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempAlarm
Normal
5.1.2.11 Transceiver
The commands in this section are Transceiver specic.
ModuleTemp: Displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade.
Transcend [slot-1] >ModuleTempAlarm
+21.4 deg. C