CRAFT LINE INTERFACE (CLI)
5-18 TranScend Chassis – Operation Manual
LaserTemp: Displays the laser temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its laser temperature reading on channel 1.
Transcend [slot-1] >LaserTemp
+23.0 (deg C)
LaserPowerDbm: Displays the laser power reading in dBm.
Example #1: In this example, the module in slot 1 reports its laser power reading.
Transcend[slot-1] >LaserPowerDbm
+0.0 dBm
LaserRf: Displays the RF reading in dB.
Example #1: In this example, the module in slot 1 reports its RF reading.
Transcend[slot-1] >LaserRf
+0.0 dB
Wavelength: Displays the laser wavelength in nanometer.
Example #1: In this example, the module in slot 1 reports its laser wavelength.
Transcend[slot-1] >WaveLength
1546.12 nm
OPinPower: Displays the optical input power reading in dBm.
Example #1: In this example, the module in slot 1 reports its optical input power reading.
Transcend [slot-1] >OPinPower
-99.0 dBm
Attenuation: displays the transmit attenuation reading in dB.
Example #1: In this example, the module in slot 1 reports its transmit attenuation reading.
Transcend [slot-1] >attenuation
+4.9 dB
GainOffset: Displays the gain offset reading in steps.
Example #1: In this example, the module in slot 1 reports its gain offset reading.
Transcend [slot-1] >gainoffset
-20 steps