CRAFT LINE INTERFACE (CLI)
5-14 TranScend Chassis – Operation Manual
+25.7
OpticalPowerDbm (dBm):
-14.1
Attenuation (dB):
+16.0
Transcend[slot-1] >alarm
System
PowerAlarm:
Normal
FanAlarm:
Major
Slot 1 (FwdRcvr)
OpticalPowerAlarm:
Normal
ModuleTempAlarm:
Normal
5.1.2.9 RF Switch
The commands in this section are RF Switch specic.
ModuleTemp: Displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade.
Transcend [slot-1] >ModuleTemp
+21.4 (deg C)
RFPower: Displays the optical input power reading in dBm.
Example #1: In this example, the module in slot 1 reports its RF input power reading on input #1 (p.s. primary
optical input).
Transcend [slot-1] >RFPower 1
+3.0 (dBmV)
Switch: Displays the RF switch position.
Example #1: In this example, the module in slot 1 reports its RF switch position as on primary input.
Transcend [slot-1] >switch
Primary
thresholddBmV: Display threshold setting.
Example #1: In this example, the module in slot 1 reports its RF switch threshold as 50 dBmV.
Transcend [slot-1] > thresholddBmV
+50.0
RFPowerAlarm: Displays the alarm status of RF input power.
CHAPTER 5: