CRAFT LINE INTERFACE (CLI)
TranScend Chassis – Operation Manual 5-15
Example #1: In this example, the module in slot 1 reports the alarm status of RF input #1 power as “MajorLoLo”
(e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >RFPowerAlarm 1
MajorLoLo
SwitchAlarm: Displays the alarm status of RF switch. This alarm is raised if switch is in faulty state.
Example #1: In this example, the module in slot 1 reports the alarm status of RF switch as “Normal”
Transcend [slot-1] >switchAlarm
Normal
ModuleTempAlarm: Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempalarm
Normal
Composite Commands: The composite commands provide a quick way to poll system information and status via one
single command. The followings are example of composite command output for RF Switch.
Info:
System
SwVer:
1.6-2.f
HwVer:
3-2
ModelName:
TSD_SwCntlr
SerialNum:
01420070901234
Slot 1 (RF-Switch)
SwVer:
2.f-2.f
HwVer:
0-2
ModelName:
TSD-RXFSW
SerialNum:
01420070901234
Status:
Transcend[slot-1] >status
Slot 1 (RF-Switch)
ModuleTemp (deg C):
+25.0