CRAFT LINE INTERFACE (CLI)
5-6 TranScend Chassis – Operation Manual
PowerAlarm: Displays the system power brick alarm status.
FanAlarm: Displays the chassis fan alarm status.
5.1.2 Plug-in Commands
The plug-in commands are grouped into two types, commands that are common to all types of plug-in and that are type specic.
5.1.2.1 Common Commands
The commands in this section are common to all types of module.
SwVer: Displays the software version information of the selected plug-in.
HwVer: Displays the hardware version information of the selected plug-in.
5.1.2.2 High Sensitivity Quad Return Receiver
The commands in this section are High Sensitivity Quad Return Receiver specic.
ModuleTemp: Displays the module temperature reading in Centigrade.
Example #1: In this example, the module in slot 1 reports its module temperature reading as 21.4 Centigrade.
Transcend [slot-1] >moduletemp
+21.4 (deg C)
OpticalPowerDbm: Displays the optical receiver power in dBm.
Example #1: In this example, the module in slot 1 reports its optical receiver power reading as -8.0 dBm on channel 1.
Transcend [slot-1] >opticalPowerdbm 1
-8.0 (dBm)
Attenuation: Displays the attenuation setting in dB.
Example #1: In this example, the module in slot 1 reports its attenuation setting as 0 dB on channel 1.
Transcend [slot-1] >attenuation 1
0 (dB)
OpticalPowerAlarm: Displays the alarm status of optical receiver power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical receiver power on channel 1 as
“MajorLoLo” (e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >opticalpoweralarm 1
MajorLoLo
ModuleTempAlarm: Displays the alarm status of module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempAlarm
Normal