CRAFT LINE INTERFACE (CLI)
TranScend Chassis – Operation Manual 5-25
Attenuation: Displays the attenuation setting in dB.
Example #1: In this example, the module in slot 1 reports its attenuation #1 setting.
Transcend [slot-1] >attenuation 1
-2 dB
LaserTempAlarm: Displays the alarm status of laser temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of laser termperature #1 as “MajorLoLo”
(e.g. Major alarm with reading below the low low threshold).
Transcend [slot-1] >LaserTempAlarm 1
MajorLoLo
OpticalPowerAlarm: Displays the alarm status of the optical input power.
Example #1: In this example, the module in slot 1 reports the alarm status of the optical input power #1 as
“MajorLoLo” (e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >OpticalPowerAlarm 1
MajorLoLo
OPoutPowerAlarm: Displays the alarm status of optical output power.
Example #1: In this example, the module in slot 1 reports the alarm status of optical output power #1 as
“MajorLoLo” (e.g. Major alarm with power reading below the low low threshold).
Transcend [slot-1] >OPoutPowerAlarm 1
MajorLoLo
LockAlarm: Displays the alarm status of synthesizer lock. It’s an alarm condition when synthesizer loses its lock.
Example #1: In this example, the module in slot 1 reports the alarm status of synthesizer lock #1 as “Major”.
Transcend [slot-1] >LockAlarm 1
Major
ModuleTempAlarm: Displays the alarm status of the module temperature.
Example #1: In this example, the module in slot 1 reports the alarm status of module temperature as Normal.
Transcend [slot-1] >ModuleTempalarm
Normal