SC1000 Fiber Laser Cutting CNC System User’s Manual Version V1.00
2017 3 27
FTC related alarm
Z axis hardware down limit
alarm
The cutting head moves at the Z axis
hardware down limit.
Z axis software up limit alarm
The cutting head moves at the Z axis
software up limit.
Z axis software down limit
alarm
The cutting head moves at the Z axis
software down limit.
Z axis servo input alarm
Z axis servo driver works improperly.
Cutting head touch panel
alarm
The tips of cutting head touched the
panel.
Z axis encoder alarm
Z axis encoder has no signal
feedback/the feedback signal is in error.
FTC signal wire alarm
FTC signal wire is note well
connected/or broken.
FTC capacitance variation is
too small
FTC capacitance variation is less than
200.
FTC follow error alarm
FTC follow is out of range.(5mm in
default)
FTC is emergency stop
The running status of FTC is stop,
please go back to origin first.
Laser system alarm
Laser system unknown alarm
Laser system power alarm
Laser system external
interlock alarm
Laser output alarm
Laser system inside interlock
alarm
Laser system power supply
board alarm
Laser system current board
alarm
Laser system unknown alarm
Water cooling machine
alarm
Water cooling machine alarm