Troubleshooting Guide 62 Document #: LTRT-57601
MediaPack, Mediant 1000, Mediant 2000
11.5 How Do I Obtain the ini File Via SNMP
It is not possible to obtain (Get) the ini file directly using SNMP. The only available method
is to trigger the auto update mechanism (that uses an HTTP server, for example). The
relevant parameters are located under cSysHTTPClient.
11.6 How Do I Change Web Username and Password Via
SNMP
¾ To change the Web login user name and password, using SNMP:
1. By default, you cannot change the Web interface's user name and password, using
SNMP. To enable this option, perform one of the following:
Set the parameter WEBPasswordControlViaSNMP = 1 in the ini file (or in the
AdminPage).
Using SNMP, set acSysGenericINILine to WEBPasswordControlViaSNMP = 1
and then reset the device with FLASH burn (set acSysActionSetResetControl to 1
and acSysActionSetReset to 1).
2. Change the user name and/or password using the SNMP table
acSysWEBAccessEntry. Use the following format:
Username acSysWEBAccessUserName: old/pass/new
Password acSysWEBAccessUserCode: username/old/new
11.7 How Do I Reset the Device Via SNMP
¾ To reset the device using SNMP:
1. Determine the reset method you want to apply to the device, using the parameter
acSysActionSetResetControl.
2. Reset the device by setting the parameter acSysActionSetReset to 1. The available
options are:
resetFromFlashAfterBurn(1) – resets the device and saves ('burns') the
configuration to flash memory.
resetFromFlashNoBurn(2) - resets the device without 'burning' the configuration to
flash.
resetFromBootP(3) – similar to a physical reset.
11.8 How Do I Force the Device to Send a SIP REGISTER
via SNMP
¾ To force the device to send a SIP REGISTER message, using
SNMP:
Use the SNMP parameter h323GKRegister. This parameter performs the same
operation as the REGISTER / Un-REGISTER buttons on the Web interface.

Table of Contents

Other manuals for AudioCodes MediaPack MP-11 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes MediaPack MP-11 Series and is the answer not in the manual?

AudioCodes MediaPack MP-11 Series Specifications

General IconGeneral
BrandAudioCodes
ModelMediaPack MP-11 Series
CategoryGateway
LanguageEnglish

Related product manuals