336.3.4. Fieldbus terminal compartment: open
336.3.5. DeviceNet cable: connect
346.3.6. Fieldbus terminal compartment: close
356.4. Accessories for electrical connection
356.4.1. Actuator controls on wall bracket
366.4.2. Parking frame
366.4.3. DS intermediate frame for double sealing
376.4.4. External earth connection
387. Operation................................................................................................................................
387.1. Manual operation
387.1.1. Manual valve operation
397.2. Motor operation
397.2.1. Operating the actuator from local controls
407.2.2. Actuator operation from remote
407.3. Menu navigation via push buttons (for settings and indications)
417.3.1. Menu layout and navigation
427.4. User level, password
437.4.1. Password entry
437.4.2. Password change
447.4.3. Timeout for incorrect password entry
447.5. Language in the display
447.5.1. Language change
468. Indications..............................................................................................................................
468.1. Indications during commissioning
468.2. Indications in the display
478.2.1. Feedback signals from actuator and valve
498.2.2. Status indications according to AUMA classification
508.2.3. Status indications according to NAMUR recommendation
528.3. Indication lights of local controls
538.4. Optional indications
538.4.1. Mechanical position indication via indicator mark (not self-adjusting)
538.4.2. Mechanical position indication (self-adjusting)
549. Signals (output signals).........................................................................................................
549.1. Signals via DeviceNet
549.2. Status signals via output contacts (digital outputs)
549.2.1. Assignment of outputs
549.2.2. Coding the outputs
549.3. Analogue signals (analogue outputs)
5610. Commissioning (basic settings)...........................................................................................
5610.1. Type of seating: set
5710.2. Torque switching: set
5910.3. Limit switching: set
6110.4. Settings at the DeviceNet gateway
6110.4.1. Fieldbus address and baud rate setting
6110.4.2. Termination
6110.4.3. Input and output data
7010.4.4. LED
7110.5. Test run
7110.5.1. Direction of rotation at mechanical position indicator: check
3
SA 07.2 – SA 16.2 / SAR 07.2 – SAR 16.2 Control unit: electronic (MWG)
AC 01.2 Non-Intrusive DeviceNet Table of contents