EasyManua.ls Logo

Austro Engine IAE50R-AA - 6 Operating Data; Limitations; 6.1 Maximum Take - off Rating; 6.2 Maximum Continuous Rating

Default Icon
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGINE MANUAL
IAE50R AA
E1.01.05 E
Issue date: 25.Jan.2018
Page: 6-1
Revision no: 9
6 OPERATING DATA / LIMITATIONS
Static sea level ratings under the following conditions:
- International Standard Atmospheric conditions at sea level
- Generator functioning
- Liquid coolant outlet temperature 65 °C (± 5 °C)
- Standard induction pipe fitted with filter
- Power measured at eccentric shaft output
- Approved fuels
- Test bed exhaust used
6.1 Maximum Take off Rating
Max. T/O Power (minimum) 37.3. kW (50 BHP)
(Value quoted includes losses associated
with intake exhaust conditions specified.)
Max. T/O RPM 7 750 RPM
Fuel consumption (max) 24 liters / hr
Exhaust back pressure 0.21 bar ± 0.04 bar (3 psi ± 0.5 psi)
at 7750 RPM with test bed system
6.2 Maximum Continuous Rating
Max. Cont. Power 35.8 kW (48 BHP)
Max. Cont. rpm 7 100 RPM
Fuel consumption (max) 18 liters / hr

Table of Contents