EasyManua.ls Logo

Austro Engine IAE50R-AA - 19.1.4.6 Error Code Table

Default Icon
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGINE MANUAL
IAE50R AA
E1.01.05 E
Issue date: 25.Jan.2018
Page: 19-11
Revision no: 9
19.1.4.6 Error Code Table
CODE
FAILURE ITEM
DESCRIPTION
ACTION BY PILOT
DURING FLIGHT
1 1
Manifold Press 1
Sensor
Sensor faulty
Not connected
Out of range
None
Investigate after
landing
1 2
Manifold Press 2
Sensor
Sensor faulty
Not connected
Out of range
None
Investigate after
landing
1 3
Air Temperature
Sensor
Sensor short circuit or
sensor low
None
Investigate after
landing
1 4
Rotor Cooling Air
Sensor
Sensor open circuit or
reading high
None
Investigate after
landing
2 1
Supply Voltage
Supply volts decrease
Switch off non
essential electrical
devices -> then
investigate after
landing
2 2
Engine Speed 1
Error or electronic
noise has been
detected
None
Investigate after
landing
2 3
Engine Speed 2
Error or electronic
noise has been
detected
None
Investigate after
landing
3 2
Manifold Air Pressure
Difference
Difference between
MAP 1 and MAP 2
sensor too high
None
Investigate after
landing