15.4 Ground Run Check List (example)
ENGINE GROUND RUND RESULTS
Date:
A/C Reg:
Engine No:
Flight Hours:
Total Running Time (hrs meter):
QFE:
Outside Air Temperature:
Instrumentation Gauge / Alarm Function Test
Pressure
Temperature
Others
RCAO
Battery Fail Alarm
Low Fuel Pressure Alarm
Engine Coolant
Charge System Fail Alarm
OAT
ECU Error Warning
EGT 1 (optional)
Fuel Flow
Oil Low Alarm
Record data after 1 minute steady running at each condition after warm up
Engine Coolant RCAO Remarks
RPM Temp Temp
Warm up ………. ………… ……… …………
Idle ………. ……… ……… ………
5000 ………. ……… ……… ………
6000 ………. …… ……… …………
Max ………. ……… ……… ………
Idle ………. ……… ……… …………
Ign. 1 Ign. 2
Mag Drops at 6000 RPM ……… ……….
Acceleration tests (3 off) Remarks
(Idle to Max RPM response) ………………………………………………….
(1 sec throttle time) ……………………………………………….
Comments If any adjustments are made as a result of this ground run they
should be recorded and the ground run repeated
……………………………………………………………………………………………………….….
…………………………………………………………………………………………………….….
………………………………………………………………………………………………….……….
Record results in engine maintenance file !