ENGINE MANUAL
IAE50R AA
E1.01.05 E
Issue date: 25.Jan.2018
Page: 9-2
Revision no: 9
During cold starts not more than 5 x 5 second start attempts
in any 3 minute period.
9.2 Engine Start down to approximately -10 °C
The engine will start equally well with either permitted fuels.
9.3 Ground Tests
See chapter 15.
9.3.1 Full Power Check
Set WOT and note RPM achieved in relation to the minimum acceptable value as defined in
the aircraft operating manual. Check that all instrumentation is functioning and that all
parameters are within limits. Check that single ignition drops are less than 300 RPM at 6 200
RPM.