EasyManua.ls Logo

Austro Engine IAE50R-AA - Electrical Installation of the ECU

Default Icon
87 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ENGINE MANUAL
IAE50R AA
E1.01.05 E
Issue date: 25.Jan.2018
Page: 19-4
Revision no: 9
19.1.4 Electrical installation of the ECU
Description
Condition
Min
Typ
Max
Unit
Power Supply
---
9
12
14.8
V
Power supply current ECU *)
---
---
---
500
mA
Power supply current System **)
3000 rpm
---
---
2
A
GND connection ECU
---
---
---
100
mOhm
C-Meter Low side switch
---
---
---
1
A
C-Meter Low side switch
---
---
---
5
V
P-Meter Low side switch
---
---
---
1
A
P-Meter Low side switch
---
---
---
5
V
F-Meter Low side switch
---
---
---
1
A
F-Meter Low side switch
---
---
---
5
V
Tacho Low side switch
Pull-up 2k2 to Ubatt
---
---
---
1
A
TX Low side switch
(Error Lamp)
Pull-up 2k2 to Ubatt
---
---
---
1
A
RX
---
---
---
Ubatt
V
CAN Bus Termination
---
---
120
---
Ohm
CAN Bus Baud Rate
---
---
500
---
kBaud
Instrument +5V
---
---
---
2
mA
*) The suggested circuit breaker for each supply line 1 amp circuit breaker (2 x 1 amp
circuit breakers)
**) System consists of ECU, Sensors and Actuators

Table of Contents

Related product manuals