EasyManua.ls Logo

Auta AC-900 - Monitors Distribution Diagrams

Auta AC-900
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
One access
Two accesses: One video, One audio
*If the installation has less than 40 monitors
and the distance is shorter than 50 mts., the
negative wire of the rise can be supressed
*The power supply unit ALV-DIGITAL 3.5A does not give A/C current
(R-C). So it has to be installed with and ATF-12 power supply unit
to release the electrical strike & to light the cardholder
POWER SUPPLY
ATF-98
10
UP TO
PHONES
UP TO
MONITORS
20
ALV-3.5A + ATF-12*
40
80
*If the installation has less than 40 monitors
and the distance is shorter than 50 mts., the
negative wire of the rise can be supressed
DIGITAL
16
VIDEO DOOR ENTRY SYSTEM
+
+
R
-
-
C
220V
C
R
-
-
+
Vi
-
b
Vi
a
Vo
b
Vo
a
C
R
CONTROL
MODULE
DOOR OPENER
C
R
-
-
+
Vi
-
b
Vi
a
Vo
b
Vo
a
C
R
CONTROL
MODULE
DOOR OPENER
ATF-12
220Vac
C4231 PAL
12345 876
ON
C4231 PAL
12345 876
ON
C
R
-
-
+
Vi
-
b
Vi
a
Vo
b
Vo
a
C
R
CONTROL
MODULE
DOOR OPENER
+
+
R
-
-
C
220V
MONITORS DISTRIBUTION
(See pages 38 to 40)
C4231 PAL
12345 876
ON
ATF-98
ATF-98
4 3 2 1: (1,2,3,4), CODE EXTERNAL PANEL
C: (6), CALL TO CENTRAL: ON - OFF
A: (7), SELF STARTING: ON - OFF
P: (8), PANEL MAIN - AUXILIARY
CODE OF AUDIO/VIDEO PANELS WITH KEYBOARD
L: (5), LANGUAGE SELECTION: A - B
SCHEMATIC
REPRESENTATION
ON
12345678
4321LCAP
1
4
CODE
3
4
ON
21
2
3
AP
7856
CL
MONITORS DISTRIBUTION
(See pages 38 to 40)
*
*

Table of Contents