6.4 Table IIC
Level II Program Values - 962 Twin Tank Alternating Softener (P17=2)
Parameter
Description of
Program Values
Range of Values
Min.
Increment
Factory
Value
Units of Measure Notes
P1 Day of Week and
Time of day
(1-7) 1:00 - 12:59
AM or PM
Metric
(1-7) 0:00 - 23:59
(1 day)
1 minute
None Hour
Minute
Range depends on value selected for
P13. For day of week SUN=1, MON=2,
TUE=3, WED=4, THU=5, FRI=6, SAT=7.
THIS IS THE LEFT MOST DIGIT ON
THE DISPLAY.
P2 Time of day to start
regeneration
1:00 - 12:59 AM or PM
00:00 - 23:59
1 None Hour
Minute
Range depends on value selected for
P13. Use only if P15 =1
P3 Hardness of water 3-250
30-2500
1
10
0
0
Grains per gallon
ppm
Unit of measure depends on value
selected for P12
P4 Salt amount 5 – 1250
2 - 500
5
2
10
4
Pounds
Kilograms
Unit of measure and factory value
depend on value selected for P12
P5 Capacity of unit 1-2600
0.1-260.0
1
0.1
0 Kilograins
Kilograms
Total capacity for each tank. Unit of
measure depends on value selected for
P12
P6 Refill controller 2 - 99 1 0 Selected from chart in
Performance Data Sections, page 57
P7 Brine draw rate 2 - 99 1 0 Selected from chart in
Performance Data Sections, page 58
P9 Backwash time 4 - 30 1 14 Minutes
P10 Rinse time 7 - 125 1 40 Minutes
P11 Purge time 2 - 19 1 4 Minutes
P12 Units of measure 0 - 1 1 0 0 = US, 1 = Metric
P13 Clock mode 0 - 1 1 0 0 = 12 hour clock, 1 = 24 hour clock
P14 Calendar override 0 - 30 1 0 Days 0 = no calendar override
P15 Regeneration
delay
0 - 1 1 0 0 = Immediate regeneration
1 = Regeneration delayed until time pro-
grammed in P2 is reached
P16 Capacity that must
be left on 2nd tank
to permit delayed
regeneration of 1st
tank
0 - 70 1 30 Percent of Total
capacity
Used only if P15 is set to 1
P17 Operation type 0 - 2 1 2 2 = Twin Alternating
P18 Salt/Capacity
Change Lock Out
0 - 1 1 0 0 = none 1 = Salt /Capacity Change
Locked Out
P19 Flow Sensor select 0 0 = Magnum IT NHWB, 1 = 1.0" Autotrol
Turbine, 2 = 2.0” Autotrol Turbine, 3 =
User defined
K-factor, 4 = User defined pulse
equivalent, 5 = Magnum IT HWB
P20 K-factor or Pulse
equivalent
0.01 -255.00 .01 0.01 Number used for Meter K-factor or Pulse
equivalent
P21 Remote
Regeneration
Switch Delay
1 - 254 1 60 Seconds Time remote switch must be active to
start a regeneration.
P22 Factory Use Only
– DO NOT
CHANGE
99
Do not change