Local administrative options
52 SIP Deskphones Release 6.4 Installation and Maintenance Guide
Use the following procedure to turn the debug mode for the button module serial port on or off.
!
CAUTION:
CAUTION: A DEBUG setting of “On” disables any button module plugged into the MOD jack
on the underside of the deskphone.
1. Use the Craft password to gain access to the Admin Procedures screen.
2. When you select DEBUG from the Admin Procedures screen, the following text displays:
where the setting shown is the text equivalent of the current numeric value assigned to the
DEBUG_ENABLED parameter, defined as:
“On” if DEBUG_ENABLED is 1.
“Off” if DEBUG_ENABLED is 0.
3. Use the navigation arrows or press Change to toggle between the options.
4. Press Save to store the new setting.
The deskphone saves the new value.
Note:
Note: Restart the deskphone for the DEBUG settings to take effect.
Setting the Group identifier
Use the following procedure to set or change the Group Identifier.
Note:
Note: Perform this procedure only if the LAN Administrator instructs you to do so.
For more information about groups, see
The GROUP parameter on page 72.
1. Use the Craft password to gain access to the Admin Procedures screen. The default
password is 27238.
2. When you select GROUP from the Admin Procedures screen, the following text displays:
where the setting is the current system value of GROUP.
3. Enter a valid Group value (0-999).
Note:
Note: Any changes that you make to the Group value results in the restart of the
deskphone when you exit the Craft menu.
Debug Mode On
Setting: