Model E1010 Indicator Service Manual
TARGET
(Checkweighing application)
Supervisor Menu—SETUP submenu (continued)
27. Press the UNITS key…
CLEAR is displayed. Use this item to clear all the information
stored for this application. WARNING - Only do this if you are
sure you want the information permanently removed!
You may want to print out the report before clearing all the informa-
tion.
28. Press the ENTER key…
SURE? is displayed.
29. Press the ESC key to abort the save process or press the ENTER key to
clear all the information…
CLEAR is displayed.
30. Press the SELECT key…
BATCH is displayed.
1. Press the UNITS key…
TARGET is displayed. Use this item to print and clear reports for
the checkweigher application and to set the type of sampling to be
used, Net or Sample.
2. Press the PRINT key…
PRINT is displayed. Use this item to print out a complete report of
checkweigher information.
3. Press the ENTER key …
Display shows BUSY briefly then returns to PRINT.
4. Press the UNITS key…
TYPE is displayed. Use this to set the way you set the target
weight for the checkweighing application. You have two choices;
LIMIT and SPL (sample).
LIMIT You enter the upper and lower limits for your item and the
indicator will use those values to run the checkweighing
graph on the top center of the display. This setting allows
an Accept range. Each segment of the fan graph will equal
one division.
SPL This method allows the user to place a correct weight
“product” on the scale to set the target weight. The
indicator will use this weight to run the display. Upper and
lower limits will automatically be 1 division above and
below the target weight respectively. Each colored display
graduation is equal to 1 scale division. The TARGET light
stays lit if weight is ±1 division of the target weight.
5. Toggle between the choices by pressing the TARE or UNITS key. Press
the ENTER key when your choice is displayed…
TYPE is displayed.

Other manuals for Avery Weigh-Tronix E1010

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Avery Weigh-Tronix E1010 and is the answer not in the manual?

Avery Weigh-Tronix E1010 Specifications

General IconGeneral
BrandAvery Weigh-Tronix
ModelE1010
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals