2-22
4)  Mounting procedure for flameproof cable gland
The procedure for mounting the flameproof cable gland is shown below.
Step Procedure
1
Securely screw the main unit of the adapter into the 
conduit connection port of the terminal box or into the 
flameproof universal elbow, and fasten the hexagon 
socket bolt.
Handling Precautions:
Apply adequate waterproofing to these parts. We 
recommend the use of silicone resin based non-
hardening seal materials.
2
Refer to the illustrations and insert the cable carefully.
Warning
If the diameters of the cable and the packing do 
not match each other, the propagation of flame 
cannot be prevented. Refer to the table below 
and select a packing adaptor whose internal 
diameter matches the outer diameter of the cable.
Cable outer 
diameter 
(mm)
Packing inner 
diameter 
(mm)
Notes
7.0
〜
8.0 8 Provided
8.0
〜
10.0 10 Built in
10.0
〜
12.0 12 Provided
The cable outer diameter is 8mm max., fix the cable 
gland with the clamps.
Handling Precautions:
Pay attention to the surface of the device. Tools may 
cause damage the surface.
3
Screw the gland into the main unit of the adapter to 
secure it in place.
Warning
To prevent injuries due to a spark travel, be sure 
to tighten down the packing adequately.
4
Pass the cable through the body and insert it into the 
terminal box.
5
Screw the union nut onto the body and tighten it down 
securely to hold it in place. Then, tighten the union nut's 
recess screw.