M2000 register write properties Page 26/30
MID_M2000_BA_MODBUS_02_1805
No Register name
Register
address
Min.
value
Max.
value
Value definition
** Req.
Action
request
69
Output #3:
Full scale frequency
[Hz]
0x00B2 0 10000 --
70
Output #3:
Flow alarm minimum
[%]
0x00B3 0 100
1 = 1%
100 = 100%
YES
71
Output #3:
Flow alarm
maximum [%]
0x00B4 0 100
1 = 1%
100 = 100%
YES
72
Output #3:
Output mode
0x00B5 0 1
0 = Normally open
1 = Normally closed
YES
73
Output #3:
Hardware select
0x00B6 0 1
0 = Relay
1 = Open collector
YES
74
Output #3:
Output operation
0x00B7 0 11
0 = Off
1 = Flow alarm
2 = Empty pipe alarm
3 = Error alarm
4 = Forward pulse
5 = AMR pulse
6 = Reverse pulse
7 = Frequency output
8 = Preset batch output
9 = Flow direction
10 = Verification test
11 = 24V DC supply
YES
** Command action code 0x01 should be issued to the command action request register
immediately following any non volatile register uptdate**