Section
2–4
MN1229
Signal Levels
Description Unit DBSC 102 DBSC 105
Command Input
VDC ±10
Command Signal Resolution bits 12
A/D Conversion Rate
sec 476
Control Inputs - X3-6, X3-7, X3-9, X3-10,
X3-1
1, X3-12, X3-13, X3-16, X3-17
VDC
+12 to +29
Feedback System Resolver
Feedback Resolution V
elocity
1500 RPM
V
elocity
6000 RPM
V
elocity > 6000 RPM
bits 16
14
12
Resolver Pole Paris
1
Resolver Winding Ratio
0.5
Encoder Output RS422
Encoder Resolution ppr 512 / 1024
1
/ 2048 / 4096
Pulse & Direction Input
RS422
(Galvanically Isolated)
Maximum Input Frequency KHz 500
Optional Handwheel Input (Pulse Follower)
RS422
(Encoder interface - A & B)
Maximum Input Frequency KHz 500
Communications Interfaces
RS232 / 422 / 485
(Not galvanically Isolated)
Data Communications Rate
Baud 9600 (Fixed)
1
Factory Setting.
Signal Levels
Description Unit DBSC 102 DBSC 105
Command Input VDC ±10
Command Signal Resolution bits 12
ND Conversion Rate lisec 476
Control Inputs - X3-6, X3-7, X3-9, X3-10, VDC +12 to +29
X3-11, X3-12, X3-13, X3-16, X3-17
Feedback System Resolver
Feedback Resolution Velocity <1500 RPM bits 16
Velocity <6000 RPM 14
Velocity > 6000 RPM 12
Resolver Pole Paris 1
Resolver Winding Ratio 0.5
Encoder Output RS422
Encoder Resolution ppr 512 / 10241 / 2048 / 4096
Pulse & Direction Input RS422
(Galvanically Isolated)
Maximum Input Frequency KHz 500
Optional Handwheel Input (Pulse Follower) RS422
(Encoder interface - A & B)
Maximum Input Frequency KHz 500
Communications Interfaces RS232 / 422 / 485
(Not galvanically Isolated)
Data Communications Rate Baud 9600 (Fixed)
1 Factory Setting.
2-4 MN1229
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com