3–10
MN1229
Serial Interface Wiring
Serial Interface
The Serial interface (DB9 connector X6) is used for communication with a PC
(Personal Computer) or other equipment.
RS232 - Not available in model DBSC 10X-BXX.
For the RS232 interface, a standard shielded modem cable can be used for
connection to a PC. If the cable is straight through (pin to pin), a null modem
connector must be used.
These are the only RS232 signals supported by the DBSC control. Mode is
jumper selectable as described in Section 4 of this manual.
RS422/RS485 - Not available in model DBSC 10X-AXX.
RS422/RS485 is a factory installed and jumper selectable in models DBSC
10X-EXX and DBSC 10X-FXX. Mode is jumper selectable as described in
Section 4 of this manual.
Figure 3-7 RS232 Interface
RD
TD
GND
RTS
CTS
+5VDC
X6 PC
TX+
TX–
GND
RTS–
CTS+
RS232
RS422/RS485
(Optional)
1
2
3
5
4
6
8
7
9
1
2
3
5
4
6
8
7
9
RX–
RX+
RTS+
CTS–
X6 PC
1
2
3
5
4
6
8
7
9
1
2
3
5
4
6
8
7
9
Note: The +5VDC at X6-9 can be used to power hand held display
terminals. Maximum rating of this power source is +5VDC at 350mA.
Serial Interface Wiring
X6
RS232
PC X6
1 1 1
RD
2 2 2
TD
3
3 3
4 4 4
5
GND
5 5
6 6 6
RTS
7
7 7
CTS
8 8 8
9 9
+5VDC
TX+
RX+
RX-
GND
RTS-
RTS+
CTS+
CTS-
Serial Interface
The Serial interface (DB9 connector X6) is used for communication with a PC
(Personal Computer) or other equipment.
RS232 - Not available in model DBSC 10X-BXX.
For the RS232 interface, a standard shielded modem cable can be used for
connection to a PC. If the cable is straight through (pin to pin), a null modem
connector must be used.
These are the only RS232 signals supported by the DBSC control. Mode is
jumper selectable as described in Section 4 of this manual.
RS422/RS485 - Not available in model DBSC 10X-AXX.
RS422/RS485 is a factory installed and jumper selectable in models DBSC
10X-EXX and DBSC 10X-FXX. Mode is jumper selectable as described in
Section 4 of this manual.
Figure 3-7 RS232 Interface
RS422/RS485
TX- (Optional) PC
1
2
3
4
5
6
7
8
9
Note: The +5VDC at X6-9 can be used to power hand held display
terminals. Maximum rating of this power source is +5VDC at 350mA.
3-10 MN1229
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Baldor DBSC 100 Series and is the answer not in the manual?

Baldor DBSC 100 Series Specifications

General IconGeneral
BrandBaldor
ModelDBSC 100 Series
CategoryController
LanguageEnglish

Related product manuals