EasyManua.ls Logo

Baldor FPX A05T - Page 109

Baldor FPX A05T
110 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B-18 Command Set
MN1276
Homing
Parameters:
Command Description Units Range Default E
2
/ Par. set
HOM.ACC Queries / updates HOME acceleration RPM / 10ms 1 : 65535 E/P2
HOM.VEL Queries / updates homing velocity RPM --2500 : 2500 E/P2
HOM.TYPE Queries / updates HOME type:
1 -- ZERO is found by Home Flag and
Resolver zero respectively Encoder
Index
2 -- ZERO position is captured at Home Flag
edge
3 -- Actual position is defined as ZERO
-- 1:3(resolver)
1, 3(encoder)
E/P2
HOM.OFFSET Queries / updates HOME offset counts +/ -- limit E/P2
HOM.POLR Queries / updates HOME switch polarity:
0 -- active low, 1 -- active high
-- 0:1 resolver)
0 (encoder)
E/P2
Variables:
Command Description Units Range Default E
2
/ Par. set
HOM.STATUS 0 -- power up (i.e. homing not done yet)
2 -- moving out of Home area (only, if HOME
is commanded while the drive is standing
in the Home area)
5 -- moving in specified direction, waiting for
Home Signal
10--homemotionfinished(1,3,4,6,7,8,9
-- in between status)
0..10 -- / --
Methods:
Command Description Parameter Units Range
HOME Executes homing the drive according to previously defined
parameters HOM.*, if motion command source is set to
software (MOT.SRC=0)
-- -- --

Table of Contents