5-8 Operation
MN1276
Current Parameter
Nominal and peak current values are automatically entered for the motor type.
For manual tuning only, set the control current limit value to a percentage of the
continuous current rating. For example, if your control is rated for 5A continuous
current and you desire to limit the output current to 4A, enter 80%. If you wish to
use the full output power of the control, enter 100%. Click Download” when
finished.
Figure 5-5 Current Parameter Screen
Velocity Parameter
Set the velocity parameters of the control:
1. Scale factor - ratio of the input voltage to output RPM.
2. Minimum velocity
3. Time to maximum velocity
Click “Download” when finished.
Figure 5-6 Velocity Parameter Screen