11. Maintenance
11.9 Auth orization to clear security warning on the projector
When is an authorization required to clear the security warning?
If a module on the Input & Communication side has been removed or if the sealed compartm ent has been opened, an authorization
will be r equired to clear the security war ning.
Necessary tools
Security key (D allas iButton®).
Authorization pin code.
Authorization procedure to clear security warning
1. Ensure that all mo dules on the Input & Communication panel are properly installed.
2. Start up the projector ( standby mode).
3. Initiate authorization by holding the security key in the security socket D..
1
1
2
3
4
5
6
Image 11-8
Keypad
The color of the backlight of the numeric keys 1 to 6 of the loc al keypad changes from blue to yellow.
4. Enter pin code within 5 seconds. Maximum ve (5) attempts perm itted.
- In c ase no keys are pressed, the color of the backlight of the numeric keys 1
to 6 changes back to blue.
-Incaseofanincorrect code entry, the color of the bac klight of the numeric ke ys changes to red for 1 second and then back
to blue.
- Incaseofacorrect code entry, the color of the bac klight of the numeric keys 1 to 10 changes to green for 1 seco nd and
then back to blue.
Each attempt to clear the security warning and its result (successfully or unsuccessfully) is logged inside the
projector.
R59770351 DP2K-20C 02/02/2010 113