Usage
The ULC-30A is designed and manufactured for the purpose of cooling the lasers and DMD of the laser projector. Cooling is estab-
lished by means of a liquid so lution made o f glycol and demineralized water.
A circulation pump forces the coolant to circulate inside a c losed circuit where it acquires the h
eat generated by the equipment being
cooled. The radiator dissipates the heat acquired by the coolant by means of ambient temperature air generated by a fan.
The ULC-30A can be used either separately or coupled with another chiller of the same type. Two ULC-30A units are c onnected by
means of a serial connection.
The ULC-30A is controlled by the projector by means of a s erial connection.
Main parts
D F
CGAB
E
Image 3-1
A Main pump unit
B Pressurization unit
C Refrigeration unit
D
Cooling fan unit
E
Secondary cooling unit
F Electronic equipment unit
G Coolant tank