System description
9
Instruction Manual PETRO 3003 VOLUTANK Gauging unit BA 140918
3.2 Technical Data
Electrical data
Power supply
AC 400 V 50 Hz max. 4 kVA
Backup fuse
Line cut-out 3x16 A (characteristic C)
A universal residual-current circuit-breaker is
recommended.
The leakage current can exceed 30 mA when the unit
is switched on!
Compressed air
6 bar to max. 8 bar
MID measuring accuracy
+-0.3% in 25l/min to 500l/min range
(but not less than +- 0.2l)
Pump output
Max. 300 l/min
Ambient conditions
Operating temperature
+15 °C … +35 °C
Storage temperature
+5 °C … +50 °C
Mechanical data
Dimensions
See dimensional drawing
Weight
Approx. 190 kg
Sound pressure level
Approx. 90 dB(A)
Hose connection
ELAFLEX MK 50 conforming to DIN EN 14420-6
(DIN 28450)
Network connection
RJ45