Servicing, maintenance and cleaning
45
Instruction Manual PETRO 3003 VOLUTANK Gauging unit BA 140918
6 Servicing, maintenance and
cleaning
CAUTION!
● Servicing, maintenance, repair and cleaning work may only be carried out
with the unit switched off. The unit must be switched off at the mains and
measures taken to prevent it from being switched on accidentally.
● Servicing work on the unit may only be carried out by trained personnel.
● Never allow the pump to run without its cover, not even for servicing
purposes.
● Do not clean the gauging unit with a jet washer.
6.1 Maintenance schedule
Check housing/pins for damage
Check function and check for damage/leaks
Check safety guards are firmly in place
CAUTION:
Do not operate the unit if safety guards are
missing
Compressed air con-
nection
Check compressed air connection for leaks
Check/clean/replace filter regulator filter
Clean sound absorbers, replace if necessary
Twice a year
Yearly
Yearly
Check impeller for damage
Grease impeller with Vaseline
CAUTION:
Do not operate pump with the housing
open. Risk of injury!
Check housing for damage
Check valves are tight and in working order
Check for leaks
Check for cleanliness
Check tip of sensor is clean
Remove and clean if necessary
Check cables and lines for damage. If cables
and lines are damaged, do not operate the
unit again until the cables and lines have
been repaired
CAUTION:
Make sure the unit is switched off. Switch the
unit off at the mains and take measures
to prevent it from being switched on accidentally.