00374 - Edition 01 - September 11
Maintenance
M1
Non-contractual illustrations
D400 - Maintenance operations
After 400 hours (P1 Service)
After 300 hours (P2 Service)
SAFETY WARNING
Users should carefully read the safety instructions prior to any intervention.
Summary of maintenance operations
b engine oil change 1/6
b oil sump lling 3/6
b oil lter replacement 4/6
b bleed the water separator lter (option) 4/6
b cleaning the fuel prelter (option) 5/6
b inspection and replacement of the zinc anode 5/6
b nalising operations
M1
5/6
M1
Fill in the maintenance table on sheet D1000
Engine oil change
b Manual pump: use the manual pump, with the engine
switched off, to change the oil.
b Check that the 3-way valve is in "Oil change" position as
indicated below, and activate the sump pump manually.
b Reposition the 3-way valve to "Pre-greasing" position once
the oil has been changed.
b Fill the engine casing with oil.
PR Catalogue
see chapters
03
04
05
Sump pump
Pre-greasing
Oil change
Oil change frequency
Note: see DT 04.G01 for the choice lubricant based on
service rates.
DT 04.G01
Engine Nominal
power
Nominal
rating
Application Service
rate
Oil change
frequency
hp (kW) mn
-1
6 M26.2
450 (331) 1800 P1 4 400
500 (368) 1800 P1 4 400
500 (368) 1900 P1 4 400
550 (404) 1900 P2 5 300