EasyManua.ls Logo

Baumer Absolute encoder - 9.7 0 x6003 Preset value encoder; 9.8 0 x2103 Group Extension

Default Icon
27 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Baumer_EAM580_360_SAE_J1939_MA_EN_Rev0003.0000h_Index0002.docx Baumer Electric AG
06.08.2018 21/27 Frauenfeld, Switzerland
9.7 0x6003 Preset value encoder
The position value of the encoder can be preset by writing the desired position to this object. The preset position value is
a 32-Bit value.
Example of setting the position to 0x52660204
Protocol Data Unit (PDU)
Description
Identifier
DLC
Byte 0 … 7 [hex]
Write preset Position to Encoder
18EFAC00h
8
22
03
60
00
04
02
66
52
Successful response by encoder (60h)
18EF00ACh
8
60
03
60
00
00
00
00
00
Optional send saving of all parameters
18EFAC00h
8
22
10
10
01
73
61
76
65
Optional successful response by encoder
(60h)
18EF00ACh
8
60
10
10
01
00
00
00
00
Cyclic PGN65450 with new Position Value
18FFDDACh
8
04
02
66
52
00
00
00
00
9.8 0x2103 Group Extension
The group extension is a 8-Bit value, which is transmitted in Byte 4.
Example of changing the Group Extension to 55h
Protocol Data Unit (PDU)
Description
Identifier
DLC
Byte 0 … 7 [hex]
Cyclic PGN65450 with Group Ext. 00h
18FFAAACh
8
18
91
B7
73
00
00
00
00
Changing Group Extension to 33h
18EFAC00h
8
22
03
21
00
33
00
00
00
Successful response by encoder (60h)
18EF00ACh
8
60
03
21
00
00
00
00
00
Optional Send saving of all parameters
18EFAC00h
8
22
10
10
01
73
61
76
65
Optional Successful response by encoder
(60h)
18EF00ACh
8
60
10
10
01
00
00
00
00
Cyclic PGN65450 with Group Ext. 33h
18FFDDACh
8
18
91
B7
73
00
00
00
00
Example of Reading Group Extension
Protocol Data Unit (PDU)
Description
Identifier
DLC
Byte 0 … 7 [hex]
Read Group Extension of encoder
18EFAC00h
8
40
03
21
00
00
00
00
00
Response by encoder with 00h
18EF00ACh
8
4F
03
21
00
00
00
00
00

Related product manuals