100
SequencerFeatureEnable true/false [RO]
Enables / disables the se-
lected feature.
SequencerSetSelector 0…127
Selects the sequencer set
that contains the feature
settings coming afterward.
SequencerSetSave -
Stores the current device
settings to the selected
sequencer set.
SequencerSetLoad -
Loads the currently select-
ed sequencer set.
SequencerSetActive 0…127 [RO]
Displays the currently active
sequencer set.
SequencerSetStart 0…127
Denes the initial sequenc-
er set.
SequencerPathSelector 0…3
Selects the path that con-
tains the settings coming
afterward.
SequencerSetNext 0…127
Denes the Set, that will be 
next.
SequencerTriggerSource
Counter1End
Counter2End
ExposureActive
Line0
ReadoutActive
Timer1End
Off
Denes the internal or 
external event that is used
as trigger source for the
Sequencer.
SequencerTriggerActivation
RisingEdge
FallingEdge
AnyEdge
Denes the signals edge 
that triggers the Sequencer.