4.2.1 EmergencyshutdownatOvertemperature(≥Rel.2only)
To prevent damage on the hardware due to high temperatures, the camera is equipped
with an emergency shutdown. The DeviceTemperatureStatusTransitionSelector (Catego-
ry: Device Control) feature allows you to select different thresholds for temperatures:
NormalToHigh: freely programmable value
HighToExeeded: xed value (camera shutdown if exceeded)
ExeededToNormal: freely programmable value, temperature for error-free re-ac-
tivation of the camera.
In the DeviceTemperatureStatusTransition feature, the temperatures for the programma-
ble temperature transitions are set.
The Event EventDeviceTemperatureStatusChanged is always generated when Device-
TemperatureStatus changes.
If the temperature rises above the value set at HighToExceed, the DeviceTemperatureEx-
ceeded feature is set to True, the image recording is stopped, and the LED is set to red.
For further use, the camera must disconnected from the power supply after cooling down
or a device reset should be carried out.
The  sufcient  cooling  is  recognizable  when  the  event  EvenDeviceTemperatureStatus-
Changed (Device Temperature < ExceededToNormal) is output.
NormalToHigh
freely programmable value
HighToExceed
fixed value (camera shutdown if exceeded)
ExceedToNormal
(Device Temperature < ExceededToNormal)
freely programmable value
Time
Temperature
Event:DeviceTemperature-
StatusChanged
Event:DeviceTemperature-
StatusChanged
Event:DeviceTemperature-
StatusChanged