EasyManua.ls Logo

BayTech DS2-RPC DS4-RPC User Manual

Default Icon
96 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background image
DS-RPC OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
__________________________________________________________________________________________
24
Binary Mode If binary data containing the port select code
is sent to a module, the DS-RPC may
interpret the data as a command to change
ports. Binary mode prevents such an
occurrence by placing the DS-RPC in a
mode which does not look at the data. This
provides a reliable binary data transmission.
However, before a connection can be made
to another port, the binary mode must be
terminated.
Place the port in binary mode by sending the
port select code, a capital B, and a carriage
return ($BTB). For example, if using the
default Port Select Code ($BT), place
Module 2, Port 1 in binary mode by typing
$BT2,1<cr>$BTB<cr>.
Terminate Binary From the terminal emulation software, send
Mode a BREAK condition command to terminate
binary mode. You may have to consult the
software users’ manual for the specific
BREAK condition command for the
emulation software you are using. For
example, the BREAK condition command
for PROCOMM PLUS is “Alt B.”

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the BayTech DS2-RPC DS4-RPC and is the answer not in the manual?

BayTech DS2-RPC DS4-RPC Specifications

General IconGeneral
Input Voltage120V
Power over Ethernet (PoE)No
ManagedYes
Output Voltage120V
ProtocolsSNMP, HTTP, Telnet
PortsEthernet
MountingRack-mountable
Operating Temperature0°C to 40°C

Summary

Programmable Features of DS Modules

Installation and Cabling

Detailed Operation and Configuration

Connecting to the DS-RPC

Steps for establishing serial connections using EIA-232, internal, and external modems.

Operating the DS-RPC Interface

How to interact with the DS-RPC via its main menu, select devices, and use ASCII commands.

DS71 and DS71-MD2 Configuration

Detailed guide for configuring DS71/DS71-MD2 serial port, device names, passwords, and other settings.

DS74 Peripheral Module Configuration

Procedures for configuring the DS74 peripheral module's serial port and device names.

DS73TP Network Module Configuration

Comprehensive setup for DS73TP, including IP addresses, subnet, gateway, and DNS.

RPC Operation and Configuration

Controlling and Configuring Receptacles

Instructions for managing RPC receptacles and configuring RPC settings like passwords and names.