Installation and Technical Manual

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the BECS BECSys3 and is the answer not in the manual?

BECS BECSys3 Specifications

General IconGeneral
BrandBECS
ModelBECSys3
CategoryController
LanguageEnglish

Summary

System Specifications

Electrical Specifications

Details controller and relay voltage and current ratings.

Mounting the BECSys3 Controller

Controller Mounting Procedures

Step-by-step guide for physically mounting the controller unit.

Warnings and Safety Precautions

Electrical Shock Hazard Warning

Alerts users to disconnect power before servicing the unit.

Feeder Connection Warnings

Advises on correct feeder connections to prevent chemical interactions.

Sensor Preparation and Connection

Sensor Preparation Steps

Proper handling and preparation of sensors, including wetting caps.

Sensor Connection to Controller

How to connect the pH and ORP sensors to the controller.

Wiring the BECSys3 Controller

Unit Wiring and Cover Opening

Initial steps for wiring, including opening the controller cover.

Controller Wiring Details

Wiring Power and Direct Connection

Connecting power and wiring directly to terminal blocks.

Supplying Power To Relays

How to configure relay power sources.

Relay Wiring Configurations

Wiring Relay 1 (pH Control)

Detailed instructions for wiring pH control relay (Relay 1).

Wiring Relay 2 (ORP Control)

Detailed instructions for wiring ORP control relay (Relay 2).

Relay 3 and Flow Switch Wiring

Wiring Relay 3

Configuring and wiring Relay 3 for various functions.

Flow Switch Installation and Importance

Importance and connection of flow switches for safety.

Paddlewheel Flow Switch Installation

Specifics on installing the paddlewheel flow switch.

Additional Sensor and Flow Switch Wiring

Free Chlorine Sensor Wiring

Wiring details for CCS140 and ECL6 chlorine sensors.

Dip Switch Settings Overview

Dip Switch Functions Chart

Table detailing dip switch positions and their functions.

Advanced Dip Switch Settings

Relay 3 Function Configuration

Setting dip switches for Relay 3 functions like Alarm or Booster.

Programming Menu Operations

Entering the Program Menu

Steps to access the controller's program menu with access codes.

Setting Alarm Points

Configuring high and low alarm points for pH and ORP.

System Settings Menu Operations

Calibration and Feed Delay Procedures

pH Calibration (2 Point)

Performing a two-point calibration for the pH input.

ORP Calibration (2 Point)

Performing a two-point calibration for the ORP input.

Advanced Programming Settings

Failsafe Timer Configuration

Setting failsafe timers for chemical feed systems.

Dead-zone, Relay Test, and ppm Calibration

ppm Probe Calibration (CCS140)

Calibrating the CCS140 ppm probe.

ppm Probe Calibration (ECL6)

Calibrating the ECL6 ppm probe.

Access Code Management

Normal Operation - Set Points

Modifying Set Points

Steps to change pH, ORP, and ppm set points.

Calibration and Alarm Conditions

Single Point Calibration - pH

Performing a single point calibration for pH.

Single Point Calibration - ppm

Performing single point calibration for ppm probe or calculated.

Troubleshooting and Firmware Upgrade

Calibration Error Troubleshooting

Steps to resolve 'Calibration Error' messages.

Probe Error Troubleshooting

How to address 'Probe Error' messages, often requiring probe replacement.

Sensor Maintenance Procedures

Potentiometric Sensor Cleaning

Procedures for cleaning pH and ORP sensor electrodes.

Limited Warranty Information