14. Trouble-shooting
44
Faults
Possible cause
Possible elimination of faults
Central lubrication pump
is not working
No power supply Renew fuse if available
Break in electrical cable Replace electrical cable
Central lubrication pump faulty Repair or replace central
lubrication pump
Pump element not hooked in Replace pump element
Pump is working but
does not pump
Air cushion in the delivery piston Vent central lubrication pump
Level is below min. fill level Fill the storage reservoir
Pump element faulty Replace pump element
No grease collar at all
lubrication points
Central lubrication pump is
not working
See “Central lubrication pump
is not working”
System blocked see „lubricant comes out
of safety valve“
No grease collar at multiple
lubrication points
Supply line to the secondary
distributor has burst or is
not leak-tight
Replace line
Fitting not leak-tight Tighten or replace fitting
Lubrication time (pump runtime)
too low
Adjust lubrication time (SPS)
Relevant lubrication line has burst
or is not leak-tight
No grease collar at
a lubrication point
Replace line
Fitting not leak-tight
Tighten or replace fitting
Pump speed reduced High system pressure Check system/bearing points
No damage (interim lubrication
may be required 1 to 2 times)
Lubricant comes out
of Pressure limiting valve
am Pumpenelement
System pressure too high
Check system
Progressive distributor blocked
Replace distributor
System blocked
Repair blocked/stuck bearing points
Valve spring broken Exchange pressure limiting valve
There is a fill level error
although the reservoir is
filled with lubricant
The capacity proximity switch in the
lubricant reservoir is faulty
Replace proximity switch
The cable for grease level monitoring
is faulty
Replace the cable
Supply voltage too low
Check voltage
Integrated pressure limiting valve
defective
Exchange pressure limiting valve