Benning IT 115 User Manual

Benning IT 115
67 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Installation Tester
BENNING IT 115
Operating Manual

Table of Contents

Other manuals for Benning IT 115

Question and Answer IconNeed help?

Do you have a question about the Benning IT 115 and is the answer not in the manual?

Benning IT 115 Specifications

General IconGeneral
TypeMultifunction Installation Tester
Phase sequence testYes
DisplayLCD
Protection classIP 40
Power supply6 x 1.5 V AA batteries
Operating Temperature-10°C to +50°C
Storage Temperature-20°C to +60°C
StandardsIEC/EN 61557
RCD testing10 mA, 30 mA, 100 mA, 300 mA, 500 mA
Loop impedance measurement0.1 to 1999 Ω
Line impedance measurement0.1 to 1999 Ω
Resolution0.01 Ω

Summary

Safety and Operating Instructions

2.1 General Warnings and Precautions

Covers general warnings, safety symbols, and precautions for safe operation and maintenance.

Device Description

Operating the Installation Tester

4.1 Indications and Signals

Explanation of display indicators, connection monitor, battery status, and warning/error signals.

4.2 Function Selector Switch

Guide to using the function selector switch for choosing measurements and modes.

Electrical Measurements

5.1 TRMS Voltage, Frequency, and Phase Sequence

Measuring AC/DC voltage, frequency, and determining phase sequence in electrical systems.

5.2 Insulating Resistance Measurement

Steps and precautions for measuring insulation resistance to ensure electrical safety.

5.3 Low-Impedance and Continuity Tests

Testing protective and earthing conductor connections for low impedance and continuity.

5.4 RCD Testing

Performing comprehensive tests on Residual Current Devices (RCDs) according to standards.

5.4.1 Contact Voltage (Uc)

Measuring contact voltage to assess safety and RCD performance.

5.4.2 Tripping Time (RCDt) and 5.4.3 Tripping Current (RCD I)

Testing RCD tripping time and current sensitivity to ensure proper operation.

5.4.4 Automatic RCD Test

Executing a fully automated RCD test sequence for efficiency and accuracy.

5.5 Loop Impedance and Short-Circuit Current

Measuring loop impedance and calculating prospective short-circuit current for fault protection.

5.6 Line Impedance and Voltage Drop

Measuring line impedance and calculating voltage drop in electrical installations.

5.6.1 Line Impedance and Short-Circuit Current

Determining line impedance and calculating the prospective short-circuit current.

5.6.2 Voltage Drop Calculation

Calculating voltage drop based on measured line impedance and reference points.

5.7 Earthing Resistance Measurement

Measuring the resistance of earthing connections to ensure system safety.

5.8 Protective Conductor Connection Test (PE)

Checking for dangerous phase voltage on the protective conductor connection (PE).

Tester Maintenance

Appendix C: Commander Accessories