Threading the Looper Thread with an auxiliary thread
The use of an auxiliary thread makes sense if a Looper Thread cannot be threaded automatically with the Air
Threader.
Prerequisite:
(see page53)
> Open the Threader Cover.
> Set the Air Threader Connector to the «left position».
> Prepare an auxiliary thread at a length of about 60 cm.
> Fold the auxiliary thread in half, hold the thread end with the loop in your hand and position the two
thread ends above the respective Air Threader Nozzle.
> Start the Air Threader Process until the thread ends of the auxiliary thread emerge out of the Looper Eye.
> Place the Looper Thread end at the length of about 20 cm through the loop of the auxiliary thread.
> Pull the auyiliary thread ends until the thread comes out of the Looper Eye.
> Remove the auxiliary thread.
> Place the Looper Thread under the presser foot to the back left.
Using the Threading Wire
The supplied Threading Wire can be used as a threading aid for the Looper Thread. The Threading Wire is a
wear part and not designed as a permanent threading or cleaning aid.
NOTICE
Damage by improper use of the Threading Wire
The Air Threader Pipes may be damaged. A repair by the Authorized bernette dealer is required.
> Insert and pull through the Threading Wire only in the thread flow direction.
Prerequisite:
There is no thread in the respective Air Threader Pipe.
«Threading preparation» (see page53)
> Open the Threader Cover.
> Guide the Threading wire with the end without loop through the corresponding Air Threader Nozzle
until it exits at the Looper Eye.
> Place the wanted thread through the loop of the Threading Wire.
> Pull the end of the Threading Wire until the Looper Thread exits from the Looper Eye.
> Place the Looper Thread under the presser foot to the back left.
> Close the Threader Cover.
Any malfunctions of the Air Threader System must be repaired by an Authorized BERNINA dealer.