BestCode Next Series 8 Technical Manual October 2022 Page 160 of 290
Prompt Code
Prompt Name
Prompt Description
01-0029
Shut Down
"Auto Clean disabled while device is off."
Displayed to prompt the user to confirm the request to shutdown the printer, despite the fact that
Auto Clean is enabled.
Solution 1:
Press OK to Power Off the Printer.
Solution 2:
Press Cancel to close the prompt.
Prompt Code
Prompt Name
Prompt Description
01-8001
Valve
"A valve is bad, Valve X. (X Indicates the failed Valve).
Displayed to indicate that a valve has failed the valve test.
Solution 1:
Press OK to close the prompt. Inspect valve connection and replace if Valve / Valve cable as needed
to resolve.
Prompt Code
Prompt Name
Prompt Description
01-8002
Power On
"Last shutdown due to loss of power."
Displayed to indicate that the most recent shutdown was due to a power failure.
Solution 1:
Press OK to close the prompt. Check Printhead and clean as necessary.
Prompt Code
Prompt Name
Prompt Description
01-8005
Fault
"Panic History: %ls"
Written to the event log if a unrecoverable error occurs.
Solution 1:
Press OK to close the prompt. Check Printhead and clean as necessary.
Prompt Code
Prompt Name
Prompt Description
01-8006
Vacuum Leak
"Vacuum leak detected."
Displayed to indicate that a (suspected) vacuum leak has been detected.
Solution 1:
Ensure that the Makeup Tank level is OK.
Solution 2:
Perform Venturi Testing procedure. Inspect Makeup Add lines for loose fittings and clogs.
Prompt Code
Prompt Name
Prompt Description
01-8007
InitFailed
"Internal File System initialization failed"
Solution 1:
Hardware on Main PCB is damaged. Replace the Main Board.
Prompt Code
Prompt Name
Prompt Description
01-8008
InitFailed
"USB Interface initialization failed"
Solution 1:
Hardware on Main PCB is damaged. Replace the Main Board.
Prompt Code
Prompt Name
Prompt Description
01-8009
InitFailed
"Network Interface initialization failed"
Solution 1:
Hardware on Main PCB is damaged. Replace the Main Board.
Prompt Code
Prompt Name
Prompt Description
02-0001
NO PROMPT
Fan speed set to %d."
Reports set point of the Fan in Percentage (30%-100%) to the Event Log.