5. LUBRICATION
5.1 Lubrication inspection
The actuator is grease lubricated for life, therefore under normal working conditions no
grease needs to be replaced or added.
In case of maintenance the following grease is recommended:
AEROSHELL GREASE 7 or equivalent, for ambient temperature -40 °C to 70 °C
6. ACTUATOR SETTING AND CONFIGURATION
Before connecting power to the actuator, check that the voltages are correct and according
to the indications on the nameplate. Wrong power supply could cause permanent damage
to the electrical components.
The setting of the F02 actuator can be carried out through the control panel inside the
actuator control system. To access the panel, remove the actuator cover and when setting
is complete replace the cover, following the procedures indicated below.
6.1 Removal of the control unit cover
Using a 5 mm Allen key, loosen the four screws and remove the cover.
Removal of the control unit cover.