December 2019
116
Installation, Operation and Maintenance Manual
VCIOM-08500-EN
Appendix
Appendix
Appendix A: ICON3000 / ICON3000AD
Ex db eb h IIB+H2 T4 Gb / Ex h tb IIIC T135°C Db IP66/68
Ex db eb h ia IIB+H2 T4 Gb / Ex h tb IIIC T135°C Db IP66/68
A.1 Safety Instructions
A.1.1 General
This Appendix A is supplemental to Installation, Operation, and Maintenance Manual
MAN-02-04-97-0713 and prescribes the safety instructions applicable to electric
actuators ICON3000-040 and ICON3000-050. The subject actuator is certied according
to EN and IEC Standards 60079-0, 60079-1, 60079-7, 60079-11, 60079-31, and EN ISO
80079-36, 80079-37 for protection type Ex db eb h or Ex db eb h ia for gas group IIB+H2
and Ex h tb for dust group IIIC. The actuator is suitable for installation in an ambient
temperature range from -25°C (-13°F) to +60°C (+140°F).
WARNING
Installation, conguration, commissioning, maintenance, and repairs must be performed
by approved and qualied personnel only.
The ICON3000 is designed in accordance with the applicable international rules and
specications, but the following regulations must be observed in every case:
• General installation and safety regulations.
• The proper use of personal protective devices (glasses, clothing, gloves).
• The proper use of tools, lifting equipment, and transport equipment.
A.2 Instructions for Proper Installation
WARNING
Verify that the actuator nameplate conforms to the applicable certication, ambient
temperature range, and site safety requirements.
Safety warnings and warranty will be invalidated if the ICON3000 is installed in explosive
atmospheres not covered by the appropriate grade of protection, and/or in environments
where temperatures exceed the maximum temperature specied on the product label.