EasyManua.ls Logo

Bilancial BTEK DD 700 - Remote Commands for Input;Output Management; Setting a Single Output; Resetting a Single Output

Bilancial BTEK DD 700
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
36
ADVANCED USE MANUAL DD700
2.5 Remote commands for Input/Output management
2.5.1 Setting a single output
It is possible to set output n2 of slot n1 using command:
SO n1 n2 <CR>
where:
n1 is 1 hexadecimal character that defines the position of the output
slot;
n2 is 1 hexadecimal character that defines the output number on
slot n1.
n1 = 0 (30H) output on the terminal
n1 = 1 (31H) output on slot 1
n1 = 2 (32H) output on slot 2
n2 = 1 (31H) output number 1
n2 = 2 (32H) output number 2
n2 = 3 (33H) output number 3
n2 = 4 (34H) output number 4
2.5.2 Resetting a single output
It is possible to reset output n2 of slot n1 using command:
RO n1 n2 <CR>
where:
n1 is 1 hexadecimal character that defines the position of the output
slot;
n2 is 1 hexadecimal character that defines the output number on
slot n1.
n1 = 0 (30H) output on the terminal
n1 = 1 (31H) output on slot 1
n1 = 2 (32H) output on slot 2
n2 = 1 (31H) output number 1
n2 = 2 (32H) output number 2
n2 = 3 (33H) output number 3
n2 = 4 (34H) output number 4

Table of Contents