EasyManua.ls Logo

Bilancial BTEK DD 700 - CW Remote Commands Associated to the CW Serial String (**); Scale Reset; Deleting an Entered Tare; Deleting the Top Limit of the Weighing Range

Bilancial BTEK DD 700
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40
ADVANCED USE MANUAL DD700
2.6 CW remote commands associated to the CW serial string (**)
The remote commands refer to the current scale.
The parameters to be set are (see:Setup Menu/Customisation/Outputs/Serial/Com xy):
terminal number
response to remote commands
end string character (EOL)
For the symbols used in the description of the characters on the serial line, refer to par. 2.1.
2.6.1 Scale reset
<SOH>nZ<CR>
n = terminal number; n = 2 characters (see: programming communication on serial lines)
If YES is set as the response parameter (see: programming communication on serial lines), the
terminal responds with:
<*><EOL>
2.6.2 Deleting an entered tare
<SOH>nCT<CR>
n = terminal number; n = 2 characters.
If YES is set as the response parameter, the terminal responds with:
<*><EOL>
2.6.3 Deleting the Top Limit of the weighing range
<SOH>nCO<CR>
n = terminal number; n = 2 characters.
If YES is set as the response parameter, the terminal responds with:
<*><EOL>
2.6.3 Deleting the Bottom Limit of the weighing range
<SOH>nCU<CR>
n = terminal number; n = 2 characters.
If YES is set as the response parameter, the terminal responds with:
<*><EOL>
2.6.5 CW string transmission request
<SOH>nX<CR>
n = terminal number; n = 2 characters.
The terminal responds with the CW string.

Table of Contents