IXNET dialogs Operating instructions iS10 / iS20
72 38019417000 en
7
Weight status GT0A
Example 21010000: Tare weighed, no motion, overload, outside zero setting range
digit Function Meaning
1 Tare identification Definition of tare
1 = tare not active
2 = weighed tare
3 = tare preset, manual value (EDP)
2 No motion 0 = unstable
1 = stable
3 Underload 0 = no underload
1 = underload
4 Overload 0 = no overload
1 = overload
5 Zero setting range 0 = outside zero setting range
1 = in zero setting range
6 Not assigned 0
7 Not assigned 0
8 Not assigned 0
Total recording
Command Response Description
I!RX07 I!GV01|<Subcmd>|LX02
(on EDP channel)
Total recording
The following return values can be configured in step 78, PC/EDP parameter menu:
GL15 Consecutive number
GL0A Item counter
GD1D Total of gross weight
GD1E Total of tare weight
GD1F Total of net weight
GW06 Record number
GV02 Data block 1-10 (additional character set)