Operating instructions iS10 / iS20 IXNET dialogs
38019417000 en 73
7
Tare with value definition
Command Response Description
I!GD02|kg;-3;50 I!LW00|770
or
I!LV00|LW01|
Error number
|LW02|770|LX02
Possible errors
3031 Tare value incorrect
3036 Transmitted weight value has incorrect dimension
Writing tolerance control value
Command Response Description
I!CV06|CD02|kg;-3;800|CD08|kg;-3;1000|CD03|
kg;-3;1200|LX02
I!LW00|9734
or
I!LV00|LW01|
Error number
|LW02|9734|LX02
Reading tolerance control values
Command Response Description
I?CV06|LX02 I!CV06|CD02|kg;-3;400|CD08|kg;-3;500|CD03|kg;-3;600|
LX02
CD02 Tolerance minus
CD08 Target value
CD03 Tolerance plus
Possible errors
3036 Transmitted weight value has incorrect dimension
24871 Tolerance parameter values are not correct
Start tolerance control
Command Response Description
I!CX01 I!LW00|8193