Page 171
724-746-5500 | blackbox.com
Chapter 4: Configuration
Figure 4-87. Menu Definition—EXT Units.
3. If the Tie Line should be directed from the Sub to the Master, select Master/
Slave CON Unit in the Choose Extender Type selection box.
4. Enter an appropriate extender name into the Name field.
5. Enter a port number into the Port field according to the required connection of
the Tie Line.
6. Confirm your settings by pressing the “Apply” button.
7. If you have created a Master/Slave CON Unit, select “Definition > CON Devices”
in the task area of the master matrix and press the New button.
A switchable CON Device will be created.
8. If you have created a Master/Slave CPU Unit, select “Definition > CPU Devices”
in the task area of the Master Matrix and press the “New” button.
A switchable CPU Device will be created.
9. Enter an appropriate extender name into the Name field.
10. Assign the previously configured Extender Unit to the just-created Device by
moving the Extender Unit from the Extender available field into the Extender
assigned field and save your settings by pressing the “Apply” button.
11. Connect to the Sub Matrix and repeat steps 1 to 10.